We fabricate office partition walls in our own Wembley workshop and install them across London. One team from survey to handover — no subcontracted glazing, no middleman mark-up.

  • Toughened safety glass to BS EN 12150, CE and UKCA marked
  • Single glazed, double glazed and acoustic partition systems
  • Out-of-hours and weekend installation for occupied offices
  • Free site survey across London, usually within 48 hours

Talk to us direct

No forms. Call the workshop, or email and we will come back the same working day.

What we quote for
  • Frameless glass partitions
  • Framed office partitions
  • Double glazed / acoustic partitions
  • Glass office doors
  • Manifestation & branding
  • Something else
The glazing team outside the Wembley workshop, standing in front of one of the branded glass delivery vans
The people who survey, make and fit the work. Our own teams and our own workshop at 6 Atlas Road, Wembley HA9 0JH.
Our own workshopGlass cut, processed and made up in Wembley HA9 — not bought in
FENSA registeredInstallations registered for building regulations compliance
Surveyed, not estimatedWe measure on site before anything is made
Local to LondonMon–Fri 8am–5pm · Wembley workshop

What we do

Partition systems we supply and install

Most London offices need one of four things: to split an open floor into meeting rooms, to put a manager in a quiet room without losing light, to give a boardroom acoustic separation, or to make a reception feel finished. These are the systems that do that.

Frameless glass partitions

Butt-jointed 10mm or 12mm toughened panels with a slim floor and ceiling track. The quietest look available — no vertical posts between panels.

  • 10mm / 12mm toughened
  • Clear silicone joints
  • Powder-coated track in any RAL

Framed office partitions

Slim aluminium framing around single glazed panels. The practical choice when you need doors, electrics or a mix of glazed and solid panels in one run.

  • 25mm–50mm frame profiles
  • Glazed, solid or part-glazed
  • Any RAL colour

Double glazed partitions

Two panes within a single frame for meeting rooms and boardrooms where speech privacy matters more than floor area.

  • Up to 45dB Rw depending on build
  • Integral blinds available
  • Flush both sides

Acoustic glass partitions

Laminated acoustic glass, sealed perimeters and acoustic-rated doors. Specified when a room genuinely has to be confidential, not just quieter.

  • Laminated acoustic interlayers
  • Full perimeter sealing
  • Acoustic door sets

Glass office doors

Frameless hinged, framed hinged or sliding, with patch fittings, floor springs or concealed closers to suit the traffic through the opening.

  • Single and double doors
  • Floor springs or patch fittings
  • Locks and access control prep

Manifestation & branding

Required by Approved Document K so people can see the glass. Frosted bands, gradient films, dot patterns or your logo cut into the vinyl.

  • Part K compliant
  • Frosted and printed film
  • Cut-vinyl logos

The work

What it looks like done properly

Illustrative images of the systems described above. Specification and finish are confirmed in writing with your quotation.

A double glazed acoustic glass meeting room with a slim dark frame, set within an open plan office floor
A frameless glass office door on polished stainless steel patch fittings with a floor spring set into the floor
Detail of a toughened glass partition panel meeting its slim aluminium floor track on carpet tiles

What you are actually paying for in a quote for glass partitions in London

Almost every price for glass partitions in London is built on a rate per linear metre, and that single number hides most of what matters. Two companies can quote the same twelve metre run and be thousands of pounds apart, not because one is greedy, but because one of them has read the drawing and the building properly and the other has priced a straight line. Before you compare prices, compare what each quote has actually allowed for.

The glass itself is rarely the biggest variable. A 10mm or 12mm toughened pane is close to a commodity and every serious supplier pays a similar sheet price. What moves the total is everything around the glass.

A frameless glass partition wall dividing a meeting room from an open plan London office, with a frosted manifestation band at eye height
  • Pane size. Glass gets disproportionately more expensive as sheets get taller, and past roughly three metres you are into lifting equipment, extra bodies and sometimes a glass manipulator. Dropping a design from 3.2m to 2.9m can save more than people expect.
  • The head detail. A partition that lands neatly on a suspended ceiling grid is a quick install. One that passes through the grid and seals to the structural soffit above means cutting the ceiling, re-hanging tiles and making good, which is joinery and decorating work sitting inside a glazing quote.
  • Doors. A frameless door on patch fittings with a floor spring costs several times a framed leaf on butt hinges, and it usually needs a recess cut into the floor. Door count is often the real difference between two quotes.
  • Glass finish. Clear toughened is the baseline. Low iron, acid-etched, back-painted, laminated acoustic interlayers and integral blind units each step the price up and lengthen the lead time, sometimes by four to six weeks.
  • Access and hours. Glazing an empty shell on a Tuesday morning and glazing an occupied, managed building from 7pm on a Friday are different labour rates for identical work.
  • Making good. Somebody has to patch the carpet, the ceiling tiles and the plasterboard where the old layout was. If the quote does not mention it, it is not in there.

If one quote comes in far below the others, read the exclusions before you celebrate. The usual gaps are making good, ceiling alterations, acoustic sealing in the voids, manifestation, out-of-hours working and the landlord’s licence to alter. Any one of those can turn the cheapest quote on the table into the most expensive job you have ever bought.

Three questions that separate a good quote from a bad one

  • What exactly is the head and base detail? Ask for a section drawing rather than a sentence. A drawing tells you whether anyone has actually looked at your ceiling and your floor.
  • What is the glass specification, pane by pane? Thickness, toughened or laminated, interlayer where there is one, and the finish. “Toughened safety glass” on its own is not a specification, it is a reassurance.
  • Who is doing the work? Ask whether the installers are employed or subcontracted, and ask who you telephone if a pane turns up with a chipped edge on the morning of the install.

Where glazed partitions sit in a fit-out programme

Glass goes in late. A normal office fit-out runs strip out, first-fix mechanical and electrical, partitions and doors, ceilings, second fix, flooring, decoration, then furniture. Glazed partitions are generally installed once the ceiling grid and the floor finish are down, because those two surfaces set the real dimensions and a toughened pane cannot be trimmed on site to suit a surprise.

That creates a squeeze in the middle of every programme. The survey has to happen before the glass is ordered, but the glass cannot be ordered until the surfaces it meets are final. In practice we survey after the floor and ceiling are in, which leaves a gap of a couple of weeks or more while panes are cut, polished, notched and toughened. Programmes that do not allow for that gap are the most common reason an otherwise well-run fit-out hands over late.

If the programme is genuinely tight there are two honest ways to pull it in. Use a framed aluminium system, where the frames absorb tolerance and panes can be ordered off drawings earlier with far less risk. Or split the package: survey and order the long straight runs early and leave the door openings and the awkward returns for a second survey a week later.

Will glass partition walls actually make the office quieter?

This is where expectations and physics tend to part company. A single 10mm or 12mm pane is a thin, stiff, light wall. Laboratory figures for that build-up usually land in the low to mid thirties in dB Rw. A double glazed partition using laminated acoustic panes can be tested into the low forties. Both of those are laboratory numbers, measured on a perfectly sealed sample in a test rig, and what you get in your office will be lower.

Two things eat the difference. The first is sealing. A continuous gap of a few millimetres at a head, a base or a wall junction will throw away a large slice of the rated performance, because sound follows air. The second is flanking transmission, where sound travels around the partition instead of through it: along the floor void, through a shared ceiling void, down a continuous window mullion, or through a ventilation duct that serves both rooms. Flanking is why a screen rated in the forties can still let you hear one side of a phone call.

It also helps to know what dB differences feel like to a person. A 3 dB change sits close to the threshold most people notice at all. Roughly 10 dB reads as about half the loudness. So moving from single glazing to a double glazed acoustic specification is a real, audible improvement and worth paying for in a boardroom, an HR office or a clinical room. Paying for it in a meeting room that opens onto open plan through a shared ceiling void is usually money burned.

If the brief is genuinely confidential conversations, the honest answer is often not glass. A plasterboard wall with two boards each side, mineral wool in the cavity and a proper seal up to the slab will beat almost any glazed partition for a fraction of the money. Glass buys you daylight, supervision and sightlines. Buy it for those.

Privacy: film, manifestation or integral blinds

These three get confused in almost every enquiry. Manifestation is the safety marking that stops people walking into a large pane. Decorative film is applied to the glass surface for privacy or branding. Integral blinds are slatted blinds sealed inside a double glazed unit and operated magnetically or by a motor.

  • Applied film is the cheapest and the most flexible. It can be cut to any pattern, changed when your branding changes, and if it sits at the right heights with enough contrast it doubles as your manifestation. On a sunny elevation it can lift or discolour at the edges after a few years.
  • Acid-etched or sandblasted glass is permanent, will never peel and looks considerably better close up. It cannot be altered without replacing the pane, and fingerprints and hand grease show badly on etched surfaces beside a door handle.
  • Integral blinds give full privacy on demand with nothing to dust and nothing hanging in the room. They only exist inside a double glazed unit, so they roughly double the thickness and weight of the screen, they add cost and lead time, and if a mechanism fails you are replacing a sealed unit rather than a blind.

Choose by how often you need the privacy, not by how the showroom looked. Permanent screening to a toilet corridor, a server room or a first-aid room should be etched glass. A boardroom that needs to go opaque twice a week wants integral blinds. A general floor that just needs sightlines broken up wants film, and film lets you put your branding on the glass in the same visit.

What happens to the partitions at the end of the lease

Most London office leases carry a reinstatement clause. At the end of the term you hand the space back in the condition the lease describes, which is usually a Cat A shell with ceilings, lighting and a clear floor plate. Anything you installed comes out at your cost, and if you do not do it the landlord’s surveyor prices the work and bills you for it.

That is a good reason to care how the screens are fixed. A demountable system, framed or frameless, that bolts to track at head and base can be taken down in a day or two, with the fixings filled and the ceiling and carpet patched. A partition that has been bonded in, chased into plasterboard or had the ceiling grid rebuilt around it becomes a demolition job with a skip.

Keep the setting-out drawings, the glass schedule and the O&M file somewhere you will find them in five years. When dilapidations negotiations start, being able to show exactly what was installed and that it is removable is worth real money. It is also worth checking whether your licence to alter requires removal at all. Some landlords would rather keep good glass office partitioning as an improvement than ask a departing tenant to strip it out.

When we tell people not to use glass

We would rather lose a job than install the wrong thing in it.

  • Rooms that need genuine speech privacy. Build those solid and spend the saving on better glass elsewhere.
  • Walls that need to take fixings. You cannot hang a whiteboard, a television bracket, shelving or a kitchen unit on a glass partition. If the room plan depends on wall space, you need a wall.
  • Buildings where the glass physically cannot get in. If the goods lift car is smaller than the pane and there is no stair route, the design has to change. It is far better to find that out at survey than on delivery morning.
  • Very small rooms. A 1.8 metre square glass box reads like a fish tank and nobody volunteers to sit in it. Part-height glazing over a solid dado almost always works better.

Everything else is fair game. Most offices in London would be better lit, better supervised and easier to re-let with glass partitioning than without it, and a properly specified system will outlast two or three tenancies.

How it works

From first call to finished job

Four stages, and we tell you where you are at each one.

Site survey

We measure the floor, ceiling and services on site. Office floors are rarely level and ceiling grids are rarely square — that is what the survey is for.

Fixed quotation

A written quote with glass specification, frame finish, door hardware and a fitting date. No allowances left open.

Workshop fabrication

Panels are cut, processed and toughened to the surveyed sizes. Toughened glass cannot be trimmed on site, so this stage decides the fit.

Installation

Track first, then panels, then doors and manifestation. Out of hours if your floor is occupied. We clear our own waste.

Specification

The detail, in writing

Every quote states the glass build, the standards it is made to and the hardware. If a quote you are comparing does not, that is worth asking about.

  • Toughened safety glass to BS EN 12150, CE and UKCA marked
  • Single glazed, double glazed and acoustic partition systems
  • Out-of-hours and weekend installation for occupied offices
  • Free site survey across London, usually within 48 hours
HA9

Partition glass is toughened to your surveyed sizes on Atlas Road in Wembley, then installed by the people who made it.

Standard specification. Project-specific details are confirmed in your written quotation.
ItemSpecification
Glass thickness10mm or 12mm toughened for frameless runs; 6mm–10mm in framed systems; 6.8mm–12.8mm laminated where acoustic or safety performance is specified.
StandardsToughened to BS EN 12150. Laminated to BS EN 14449. Safety glazing to BS 6206 Class A. CE and UKCA marked.
Acoustic performanceSingle glazed frameless typically 32–37dB Rw. Double glazed systems typically 40–45dB Rw depending on frame, seals and glass build.
Maximum panel sizeUp to 3000mm high and 1500mm wide as standard. Larger panels are possible but access and lifting need checking at survey.
Frame finishesAnodised, or powder-coated to any RAL. Satin stainless and matt black are the most commonly specified.
Fire ratingFire-rated glazed screens (EI30 / EI60) are available as a separate specification and are quoted individually against the fire strategy.

FAQ

Common questions

How much do glass partitions cost in London?

Price is driven by glass thickness, whether the system is single or double glazed, door hardware and access. Single glazed frameless partitions are the most economical; double glazed acoustic systems with doors cost appreciably more per linear metre. We quote per project after a survey rather than per square metre, because ceiling type and out-of-hours access change the figure more than the glass does.

How long does installation take?

A single meeting room is usually one day on site. A floor split into several rooms is typically two to four days. Fabrication before that is normally two to three weeks from the signed survey, because the glass is toughened to your measured sizes.

Can you fit partitions while the office is occupied?

Yes, and it is most of what we do. We work evenings and weekends, dust-sheet the route in, and sequence the work so a floor stays usable between visits.

Do glass partitions need a building regulations application?

Non-structural internal partitions usually do not, but the glazing has to meet Approved Document K for safety and manifestation, and you must not block means of escape or compromise fire compartmentation. If the layout affects escape routes or fire-rated construction, that needs addressing before we fabricate.

How soundproof are glass partitions really?

A single glazed frameless partition reduces speech to a murmur but will not make a room confidential. If people must not be overheard, you need a double glazed or laminated acoustic build with sealed head and base details — and the ceiling void above the partition dealt with, since sound travels over the top of an unsealed partition regardless of the glass.

Are the partitions demountable if we move or re-plan?

Framed and double glazed systems are designed to be taken down and re-used. Frameless butt-jointed runs can be removed, but silicone joints and track fixings mean panels usually need re-processing to fit a new layout.

In detail

Read up before you buy

A page on each part of what we do, written to answer the question properly rather than to sell.

Office glass partitions in London

Meeting rooms, manager offices, boardrooms and reception screens - surveyed, fabricated in our own workshop and installed around your working day.

Glass partition walls: choosing the right type for the space

Four quite different products get sold as glass partition walls, and they are not interchangeable. This page explains what separates them, how each one is actually put together, and which one belongs in the room you have in mind.

Glass office partitioning: plan the layout before you price the glass

The glass is the easy part. What decides whether a partitioned floor works is how many rooms you put in, how big they are, and what you do to the lighting, sprinklers and air handling to make room for them.

Glazed partitions: how to read and write the specification

Written for specifiers, architects and project managers who have to describe a glazed partition properly, and for clients who want to understand the document they are being asked to sign.

Commercial glass partitions for buildings that are not offices

Retail units, clinics, gyms, schools, laboratories and showrooms all buy glass partitions, and almost nothing about the specification carries over from an office. This page covers what changes, use by use.

How to choose glass partition installers in London

This page is written to help you judge us against anyone else. It sets out the questions, documents and quotation details that separate a competent installer from a company that is about to subcontract your job.

Acoustic glass partitions: reading the numbers and getting the details right

Acoustic performance is the one thing in a glass partition you cannot see, cannot judge on site and cannot fix cheaply afterwards. This page explains what the ratings mean, how to specify a target, and which construction details actually decide whether the room is confidential.

Coverage

Where we work

We cover Greater London from our Wembley workshop, with most work in north, west and central London. See the full list of areas.

  • Wembley
  • Harrow
  • Brent
  • Ealing
  • Acton
  • Willesden
  • Kilburn
  • Camden
  • Islington
  • Westminster
  • Marylebone
  • Fitzrovia
  • Mayfair
  • Kensington
  • Chelsea
  • Hammersmith
  • Fulham
  • Chiswick
  • Shepherd's Bush
  • Notting Hill
  • Maida Vale
  • St John's Wood
  • Hampstead
  • Highgate
  • Finchley
  • Barnet
  • Mill Hill
  • Edgware
  • Stanmore
  • Pinner

Get a fixed price for your partition project

Tell us the floor and what you need to separate. We will survey across London, usually within 48 hours, and quote in writing.